Symptoms:
- There's no log for the cm command by default
Resolution:
How to configure the cm log
- Locate in the directory where cm.exe exists, which is usually located where the Plastic SCM client is installed.
- Create a file named
cm.log.confThe configuration file needs to be placed in the same directory where the cm.exe exists. - Copy and paste the content from here to the file
<log4net>
<appender name="ConsoleAppender" type="log4net.Appender.ConsoleAppender">
<layout type="log4net.Layout.PatternLayout">
<conversionPattern value="%date %-5level %thread %logger - %message%newline" />
</layout>
</appender>
<appender name="FileAppender" type="log4net.Appender.FileAppender">
<file value="cm.log.txt" />
<appendToFile value="true" />
<layout type="log4net.Layout.PatternLayout">
<conversionPattern value="%date %-5level %thread %logger - %message%newline" />
</layout>
</appender>
<logger name="Serialization">
<level value="DEBUG" />
</logger>
<logger name="BufferPool">
<level value="DEBUG" />
</logger>
<logger name="MasterViewManagerGroups">
<level value="DEBUG" />
</logger>
<root>
<level value="DEBUG" />
<appender-ref ref="FileAppender" />
</root>
</log4net>
- Modify the Output Path (Optional): You can customize where the log file is created by modifying the
- For Linux: Change the line to
<file value="${HOME}/.plastic4/cm.log.txt" /> - For Windows: Change the line to